Monday - Thursday:
9:00 AM - 1:30 PM
3:00 PM - 5:00 PM
Friday:
9:00 AM - 3:00 PM
Suitable for solar installers (initial commissioning, repeat testing, troubleshooting), photovoltaic experts as well as service, cleaning and maintenance teams.
Application: Photovoltaic installation tester for standard-compliant installation and repeat testing of grid-connected photovoltaic systems according to VDE 0126-23 (DIN EN 62446).
Modern PV modules use PV cell technologies with higher efficiencies and a higher effective capacity. Due to the additional capacity, these PV modules can generate inrush currents in the event of a short circuit that are far above the specified short-circuit currents (Isc).
Advantages of the BENNING PV 1-1+
Measurements: Insulation resistance measuring range 0.05 MOhm - 199 MOhm. Nominal test voltage 250 V. Nominal test voltage 500 V. Nominal test voltage 1000 V. Nominal test voltage adjustable. Insulation resistance with good/bad indication. Protective conductor resistance measuring range 0.05 Ohm - 199 Ohm. Continuity test of protective and equipotential bonding conductors with 200 mA test current. Voltage measurement yes, 30 V - 400 V AC/DC. Automatic display of voltage polarity with acoustic/visual warning in case of wrong polarity. Open-circuit voltage up to 1000 V DC. Safe short-circuit current measurement up to 15 A DC without danger for the user. Function test by current measurement up to 40 A AC/ DC, optional BENNING CC 3 (044038). Display and storage of solar irradiation W/m2 and PV module/ambient temperature, optional BENNING SUN 2 (050420).
Special features: String-to-strand comparison with display in case of deviation > 5 %. Simple operation for fast and reliable testing with automatic test sequence (open-circuit voltage, short-circuit current, insulation resistance). Safe measurement connection when the PV system is supplying energy. Integrated real-time clock for storing the measured values with date and time stamp. Wireless Sun link to the optional irradiation/temperature measuring device BENNING SUN 2 (050420). With measured value memory for 200 photovoltaic strings. USB-A interface version, for measured value download and download software for test report generation in MS Excel. Automatic switch-off time APO adjustable up to 10 min. Power supply Battery, 6 x 1.5 V Mignon AA LR6.
Incl. test leads, crocodile clips, MC4/ Sunclix test leads, bag, 6 x 1.5 V Mignon AA LR6 batteries, download software, fuse 0.5 A (749771)
Perfomance features:
Measuring functions:
| BENNING PV 1-1 |
display | graphic display (illuminated) |
protective conductor | 0.05 Ω - 199 Ω |
testing current | ± 200 mADC |
open circuit voltage | 5 V - 1000 VDC |
short-circuit current | 0.5 A - 15.00 ADC |
insulation resistance | 0.05 MΩ - 199 MΩ |
testing voltage | 250 V, 500 V, 1000 VDC |
load current | 0.2 A - 40 AAC/DC (by means of clamp) |
measured value memory with real clock | over 200 PV strings (automatic measurement) |
interface | USB (measured value download) / radio (SUN 2) |
scope of delivery | Carrying case, carrying strap, 4mm measuring leads, crocodile clips, MC4 and Sundix PV measuring leads, |
Dimensions / Weight | 270 x 115 x 80 mm / 1.2 kg |
item no. | 05042101 |
Technical changes, model or color modifications, mistakes and delivery facilities without notice! No responsibility for literal mistakes.