Multifunction Installation Tester for Safety Testing on Electrical Installations
-
testing according to IEC 60364-6 and EN 50110
-
testing RCDs of types B / B+ (universal) and types AC, A, F (mixed frequencies)
-
even more easier, efficient and safer tests
Features:
-
NEW: bidirectional interfaces (USB / RS 232)
-
NEW: measured value memory covering four levels (object / block / fuse / measuring point)
-
NEW: upload of installation structures and download of measured values
-
NEW: integrated real-time clock (measured value with date/ time)
-
NEW: unambiguous "PASS" / "FAIL" indication by means of green / red LED on the tester and on the switchable "Commander" probe tip
-
NEW: "Commander" probe tip with "TEST" and "MEM" key as well as bright LED measuring point illumination
-
all measuring functions can be selected directly by means of a rotary switch
-
memory of measured values for 1800 measurements
-
graphic display with background lighting, help function with connecting diagram
-
power supply by means of six NiMH storage batteries (AA)
-
device with integrated storage battery charging function
Measuring functions:
-
low-impedance resistance of protective conductor and equipotential bonding conductor connections (testing current: 200 mA with polarity reversal)
-
insulating resistance with testing voltages of 50 / 100 / 250 / 500 / 1000 V
-
line impedance (L-N / L) with voltage drop and short-circuit current
-
loop impedance (L-PE) without RCD tripping and short-circuit current
-
testing of RCDs, standard and delayed (S), types AC, A, F, B, B+ with AUTO test, contact voltage, tripping time and tripping current (ramp test)
-
TRUE RMS voltage, frequency and phase sequence test
-
single-fault leakage current in IT networks
Measuring functions by means of optional accessories:
-
earthing measurement by means of three-wire measuring method by means of earthing kit
-
TRUE RMS current by means of current clamps BENNING CC 1 / BENNING CC 3
-
luminous intensity by means of BENNING luxmeter type B
BENNING PC-Win IT 130 logging software:
-
NEW: creation and transmission (upload) of installation structures to the BENNING IT 130 for efficient periodic testing
-
download of measured values and logging by means of test reports and ZVEH test certificates
Industrial environments requires TRUE RMS measuring instruments!
Non-linear loads arising e.g. from motor drives with adjustable speed, frequency converters or mains supply units for office equipment and LED lamps generate a reactive power in the mains. As a result, multimeters and current clamps working with the so-called averaging measuring method ("RMS") will display the measured values with reduced accuracy.
In many cases and particularly in industrial environments, it is therefore absolutely necessary to use state-of-the-art "TRUE RMS" measuring instruments. The "TRUE RMS" measuring method indicates the actual effective value of an alternating current correctly – irrespective of whether the signal waveform of the current is sinusoidal or distorted.
|
BENNING IT 130
|
display
|
graphic display (illuminated)
|
low-impedance resistance
|
0.01 Ω - 2 kΩ
|
insulation resistance
|
10 kΩ – 1000 MΩ
|
line impedance (L-N / L)
|
0.01 Ω – 10 kΩ
|
loop impedance (L-PE)
|
0.01 Ω – 10 kΩ
|
short-circuit current
|
0.01 Ω – 200 kA
|
RCD testing of types
AC / A / F and B / B+
|
tripping time, tripping current (ramp),
contact voltage, automatic testing (AUTO)
|
rotary field
|
yes
|
voltage (TRUE RMS), frequency
|
1 V – 550 V, 0 Hz – 500 Hz
|
earth resistance
|
0.01 Ω – 2000 Ω (by means of earthing set)
|
current (TRUE RMS)
|
0.1 mA – 400 A (by means of clamp)
|
luminous intensity
|
0.01 lux – 20 klux (by means of sensor)
|
measured value memory
|
up to 1800 measuring results
|
interfaces (bidirectional)
|
USB, RS 232
|
incl. software
|
yes
|
item no.
|
044103
|
IT 130 Bedienungsanleitung
|
Download
|
|
|
Technical changes, model or color modifications, mistakes and delivery facilities without notice! No responsibility for literal mistakes.
|